Understanding The Second Half of Code - Video 12, 2002 Emergency vs. Standby Systems, Permitted Sources of Power for Emergency Systems, Exit Lights & Emergency Lights, Separate Emergency Wiring Systems, Separate Conduit Systems & Transfer Switches, Places of Public Assembly, Hazardous Location Fundamentals, Class I Hazardous Locations, Permitted Wiring Methods, Class II Hazardous Location Fundamentals, Intrinsically Safe Wiring, Class I, Zone Locations, Gasoline Dispensing Stations, Paint Spray Booths, Health Care Facilities, Swimming Pools, Hot tubs, spas, fountains, Grounding & Bonding Around Pools. more info |
Ampacities & Derating - Video 6, 2002 Ampacity Tables, Insulation Ratings, Number of Conductors, Wiring Insulation Dictionary, Ampacity Table Values & Footnotes, Ambient Temperature Corrections, Derating Factors & Examples, Derating vs. Conduit Fill, Maintaining Spaces Between Conduits, Derating & Neutrals, Ampacity vs. Overcurrent Protection, Overcurrent Protection for Receptical Circuits vs. Lighting Circuits, 60°, 75°, 90°C Insulation Application Limitations. more info |
NEC Motor Circuits Understanding Article 430 - Video 11, 2002 Example Typical Motor Nameplate: Horsepower, Voltage, Service Factors, Code Letters & Amperages, Motor Amperage, Voltage & Service Factor, Example of a Typical Motor Circuit, Tables 430 - 148 to 152, Motor Circuit Conductor Sizing, Motor Overload Protection, Short Circuit Protection, Sizing Fuses & Circuit Breakers, Motor Feeder Protection, Motor Control Circuits, Motor Controllers, Motor Control Centers, Motor Disconnecting Means Requirements, Motor Circuit Calculations. more info |
|
NEC Residential Wiring Code - Video 3, 2002 Receptacle Requirements, Kitchen & Bathroom Receptacles, Ground-Fault Circuit-Interrupters, Arc-Fault Circuit-Interrupter, Lights, Switches & Fixtures, Appliances, Ranges & Dryers, Protection of Cables, Branch Circuit & Receptacle Loads, Maximum Permitted Loads, Clearances, Services, Requirements Affecting Existing Houses. more info |
Overcurrent Protection, Continuous Loads, Transformers and TAP Rules - Video 7, 2002 Overcurrent Protection, Protection of Transformer Secondary Conductors, Standard Fuse & Circuit Breaker Sizes, Feeder Tap Rules, Transformers Equal to or Less Than 600 Volts, Transformer Overcurrent Protection for Transformers Over 600 Volts, Transformer Overcurrent Protection of Transformer Secondaries, Transformer Tap Rules, Multiple Transformer Taps, Continuous Load Calculations: Conductor Size vs. Fuse or Circuit Breaker Size, Derating & Overcurrent Protection, Ground-Fault Protection. more info |