Electricalc Pro® Electrical Code Calculator, 2006 Updated Edition
The new 2006 Updated Edition Electricalc Pro® Electrical Code Calculator includes the 2005, 2002, and 1999 NEC Code
Features & Applications:
The ElectriCalc Pro is the world's most complete Code based electrical calculator. Solve electrical calculations in seconds; answers conform to current NEC®. It's a complete electrical reference tool that will save time, trouble and money. Update to future code revisions with an easy-to-install kit.
ElectriCalc Pro Calculator Upgrades:
- Enter BTU to find Kilowatts per Hour
- Enter Kilowatts per Hour to find BTU
- Parallel Resistance
- NEC® Table Number displayed when performing Wire Size calculations
- Ohm's Law calculations: enter any two values to solve for the third
- Circular MILS wire sizes
Features:
Electrical Measurements and Conversions
- Work directly in and convert between Amps, Watts, Volts, Volt-Amps, kVA, kW, PF%, EFF% and DC Resistance
Dedicated Functions
- Calculate wire sizes per NEC® 310-16 and 310-17; Copper or aluminum, 3Ø/1Ø, 60°C, 75°C, 90°C insulation ratings and 100% or 125% of ampacity. Adjust wire sizes for ambient temperatures other than 30°C and for more than three wires in a raceway
- Integrated voltage drop solutions. Find minimum VD wire size, maximum Length for any given wire size, drop percentage, actual number and percentage of Volts dropped
- Conduit sizing for 12 types of conduit. Per 2005 NEC® Table C1-C12, find sizing of all common conduits for any combination for #THW, #XHHW and #THHN wires. Plus, gives fill percentages, cross-sectional areas, remaining areas and more
- Find Motor Full-Load Amps per current NEC®. Works in 1Ø and 3Ø with the new expanded tables for 3Ø induction (to 500 HP), synchronous (to 200 HP) and DC motors per NEC® 430-247, 430-248 and 430-250
- Calculates Fuse and Breaker Sizes. Solves fuse and breaker sizes per NEC® 430-52
- Parallel and derated wire sizing
- Parallel Resistance
- NEC® Table number displays when performing Wire Size calculations
- Sizes overload protection per NEC® 430-32
- Automatically finds NEMA starter sizes
- Calculates service and equipment grounding conductor sizes per NEC® 250-122 and 250-66; plus works directly in electrical terms
- Enter BTU to find Kilowatts per Hour
- Enter Kilowatts per Hour to find BTU
- OHM's Law Calculations: enter any two values to solve for the third
- Circular MILS wire sizes
- Works as a standard math calculator with +, -, X, ÷, +/–, %, π, 1/x, x2 and
square root - Auto Shut-off extends battery life, Memory
- Update to future code revisions with easy-to-install kit
- Included with Every ElectriCalc Pro:
- Easy-to-follow User's Guide
- Handy Pocket Reference Guide
- Ergonomically designed Armadillo Gear® protective case
Applications:
- Electrical Contractors
- Designers
- Engineers
- Electricians
- Maintenance
- Inspectors
- Planners
- Builders
- Lighting Specialists
Spec Summary:
Size: |
5.5" x 3.0" x 0.5" (140mm x 76mm x 13mm) |
Weight: |
3.2 oz. (90.8 gm) Includes Battery, without Armadillo Gear Case 6.7 oz. (189.9gm) calculator with Armadillo Gear Case |
Power: |
One 3-volt (CR-2032) Long-life Battery |
Display: |
8 Digits with Full Annunciators |
LCD Dimensions: |
0.56" x 2.25" (15mm x 57mm) |
Accuracy: |
10 Digit Internal Accuracy |